DA-045-12-02

Overview: PowerCool Series
The DA-045-12-02 is a Direct-to-Air Thermoelectric Assembly (TEA) that uses impingement flow to transfer heat. It offers dependable, compact performance by cooling objects via conduction. Heat is absorbed through a cold plate and dissipated thru a high density heat exchanger equipped with an air ducted shroud and brand name fan. It has a maximum Qc of 42.2 Watts when ΔT = 0 and a maximum ΔT of 34.6 °C at Qc = 0.

Electrical and Thermal Performance Curves

Select Graph
Y - Axis




Select Graph
X - Axis



Imin=1.53 A
Imax=5.48 A

Vmin=4.48 V
Vmax=14.62 V
Voltage  
Current  
Click UPDATE to view changes in thermal operating conditions
Control Temp  
Ambient Temp  
Δ T  


Electrical Operating Points
Selected Operating Point
Cooling Power (Qc) = Watts
TEM Voltage = Volts
TEM Current = Amps
Fan Voltage = 12.0 Volts
Fan Current = 0.90 Amps
Power Supply = Watts
TEM COP =
Power Dissipated (Qh) = Watts
Thot = °C
Optimum COP
Cooling Power (Qc) = 11.6 Watts
TEM Voltage = 7.3 Volts
TEM Current = 2.7 Amps
Fan Voltage = 12.0 Volts
Fan Current = 0.90 Amps
Power Supply = 30.5 Watts
TEM COP = 0.6
Power Dissipated (Qh) = 42.1 Watts
Maximum Qc
Cooling Power (Qc) = 23.3 Watts
TEM Voltage = 14.6 Volts
TEM Current = 5.5 Amps
Fan Voltage = 12.0 Volts
Fan Current = 0.90 Amps
Power Supply = 90.9 Watts
TEM COP = 0.3
Power Dissipated (Qh) = 114.2 Watts


* Any information furnished by Laird and its agents is believed to be accurate and reliable. All specifications are subject to change without notice.


Specifications
Operating Temperature Range
-10°C - 46°C  ( 14°F - 115°F )
Supply Voltage
12.0 VDC nominal / 15.0 VDC maximum
Current Draw
6.1 A running / 7.0 A startup
Power Supply
73.0 Watts
Performance Tolerance
10%
Fan MTBF
50000 hours
Weight
1.20 kg ( 2.65 lbs )

Mounting Hole Location
Wiring Schematic

Notes
1For indoor use only
2Units are generally maintenance free, however occasionally it is recommended to clean the heat sinks and fans of debris. This is best done with compressed air.

DA-045-12-02


If you know your ∆T, enter that value in the box to the left of the SEARCH Button for more optimized results and click SEARCH.

Once you’ve selected a TEA product, you can fine tune your application requirements by altering values for voltage, current, control temp, ambient temp, ∆T and clicking the UPDATE button.

To view a different product, click the Back Button on your browser

Contact a Laird Thermal Expert Now